Boiler Deaerator
Boiler Deaerator

Boiler Deaerator

MOQ : 1 Unit

Boiler Deaerator Specification

  • Power
  • 5 kW (Standard, Varies by model)
  • Condition
  • New
  • Product Type
  • Boiler Deaerator
  • General Use
  • Removal of Dissolved Gases from Boiler Feedwater
  • Material
  • Mild Steel / Stainless Steel
  • Capacity
  • 500 LPH to 50000 LPH
  • Weight (kg)
  • Varies per capacity (Standard: 1500 kg)
  • Computerized
  • No
  • Automatic
  • Yes
  • PLC Control
  • Available (Optional)
  • Mixer Type
  • Spray and Tray Type Deaeration
  • Shaft
  • High Strength Shaft (Material: Stainless Steel)
  • Drive Type
  • Direct Coupling or Belt Drive
  • Voltage
  • 380/415 V, 3 Phase, 50 Hz
  • Motor
  • Standard Efficiency Motor Included
  • Dimension (L*W*H)
  • Customized as per requirement (Sample: 3000 x 1200 x 2500 mm)
  • Feature
  • Corrosion Resistant Construction, High Efficiency, Low Maintenance
  • Color
  • Metallic Grey & Blue
  • Connection Type
  • Flanged Ends
  • Insulation
  • Mineral Wool Layer with Aluminium Cladding
  • Safety Devices
  • Equipped with Pressure Relief Valve & Level Controller
  • Feedwater Temperature
  • Heats Feedwater up to 105°C
  • Test Certificates
  • Hydro Test and Material Test Certificate provided
  • Installation Type
  • Horizontal or Vertical (as per requirement)
  • Mounting
  • Skid Mounted Unit
  • Deaeration Efficiency
  • Removes up to 99% of Dissolved Oxygen
  • Distribution System
  • Stainless Steel Spray Nozzle and Trays
  • Working Pressure
  • Up to 6 kg/cm²
  • Surface Finish
  • Painted / Powder Coated / As per customer specification
 

Boiler Deaerator Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 5 Units Per Year
  • Delivery Time
  • 45-60 Days
  • Packaging Details
  • Wrapping and Wooden Packaging
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001:2008
 

About Boiler Deaerator

Boiler Deaerator

We are a certified manufacturer and supplier of a premium quality range of Boiler Deaerator. Under the guidance of our professionals, Our offered system is perfectly assembled by using premium quality components in line with predefined industry norms. The systems we provide are mainly demanded for removal of contaminants such as dissolved gases from fluid. This Boiler Deaerator is properly tested by our quality controllers on different standards and can be easily availed at pocket friendly rates.

Features:

  • Easy to install
  • Light weight
  • Excellent efficiency
  • Cost effective



Exceptional Deaeration Performance

Engineered to deliver up to 99% removal of dissolved oxygen, our boiler deaerator ensures your feedwater is virtually free from corrosive gases. The integrated spray and tray system maximizes contact and heat transfer, safeguarding boiler integrity and boosting efficiency. This results in extended equipment lifespan and reduced operational costs over time.


Intelligent & Safe Operation

The automatic control system, with optional PLC integration, streamlines operation for consistent performance. Safety is ensured through pressure relief valves and level controllers, while hydrostatic and material test certificates confirm reliability. Each unit operates with standard efficiency motors tailored for capacities, providing peace of mind during continuous use.


Customizable & Durable Construction

Manufactured from mild steel or stainless steel with corrosion-resistant finishes, the deaerator is built for longevity. Installation options include both horizontal and vertical mounting. Mineral wool insulation with aluminium cladding conserves energy, while high-strength shafts and direct coupling or belt drive options offer robust mechanical performance. Each product is tailored to installation site requirements.

FAQs of Boiler Deaerator:


Q: How does the boiler deaerator remove dissolved oxygen from feedwater?

A: The boiler deaerator utilizes a spray and tray type distribution system made of stainless steel nozzles and trays. Hot feedwater is sprayed over the trays, where steam strips away up to 99% of dissolved oxygen, reducing corrosion risks in the boiler system.

Q: What safety mechanisms are included with the deaerator unit?

A: The deaerator comes equipped with a pressure relief valve and level controller to prevent over-pressure and low water levels. These devices enhance operational safety and protect both the equipment and personnel during use.

Q: When should a boiler deaerator be installed in a steam generation system?

A: It is recommended to install the deaerator before the boiler, as part of the feedwater treatment process. This ensures that dissolved gases are removed prior to water entering the boiler, minimizing corrosion and extending boiler life.

Q: Where can the deaerator unit be mounted and what are the installation options?

A: The unit is skid mounted for easy placement and can be installed in either horizontal or vertical orientation according to your sites specifications and space requirements. Connection types are flanged for secure and reliable integration.

Q: What process does the boiler deaerator follow for heating the feedwater?

A: The deaerator heats the incoming feedwater up to 105C using steam, which is distributed through spray nozzles and trays. This process enhances deaeration efficiency and prepares the water for optimal boiler operation.

Q: How does using a deaerator benefit my boiler system?

A: By removing dissolved gases, primarily oxygen, the deaerator protects boilers from corrosion, improves steam quality, increases system efficiency, and reduces frequent maintenance requirementsresulting in lower operating costs and prolonged equipment lifespan.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email