Thermic Fluid Heaters
Thermic Fluid Heaters

Thermic Fluid Heaters

MOQ : 1 Unit Unit

Thermic Fluid Heaters Specification

  • Type
  • Thermic Fluid Heater
  • Material
  • Mild Steel
  • Storage / Tankless
  • Tankless
  • Installation Type
  • Horizontal
  • Capacity
  • 1,00,000 Kcal/hr to 20,00,000 Kcal/hr
  • Voltage
  • 220-240 V
  • Power
  • Oil/Gas Fired
  • Dimension (L*W*H)
  • Depends on capacity (Customizable)
  • Gas Type
  • Diesel, Furnace Oil, Gas
  • Tank Diameter
  • Customizable as per design
  • Color
  • Standard / Customized
  • Temperature Range
  • Up to 300°C
  • Working Pressure
  • Up to 15 kg/cm2
  • Construction Standard
  • IS 3044 / IBR
  • Thermal Oil Circulation
  • Pump Driven
  • Heat Exchanger
  • Finned Tubular Coil
  • Firing Mode
  • Automatic
  • Usage/Application
  • Industrial / Process Heating
  • Flue Gas Outlet
  • Chimney Mounted
  • Fuel Efficiency
  • Up to 87%
  • Control Panel
  • Digital / Automatic
 

Thermic Fluid Heaters Trade Information

  • Minimum Order Quantity
  • 1 Unit Unit
  • Supply Ability
  • 5 Units, , Per Year
  • Delivery Time
  • 45-60 Days
  • Packaging Details
  • Wrapping and Wooden Packging
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001:2008
 

About Thermic Fluid Heaters

In order to fulfill the diverse requirements of our valuable clients, we are involved in exporting, manufacturing and supplying of Technologically Advanced Thermic Fluid Heater in Pune, Maharashtra, India. The offered fluid heater is developed with the help of quality material in compliance with set industrial standards. This heater has maximum operation reliability which leading to high productivity. Our offered product is available in numerous specifications as per the demand of customers and delivers within a scheduled time.


Features:


Noiseless functioning

Energy efficiency

Non-corrosive



Exceptional Fuel Efficiency

Achieve up to 87% fuel efficiency with advanced combustion systems and automatic firing modes, reducing energy consumption and operational costs for industrial heating processes. The optimized finned tubular coil enhances heat transfer, ensuring better utilization of fuel and maximizing system performance.


Precise Temperature Control

Equipped with a digital/automatic control panel, the Thermic Fluid Heater allows accurate regulation of temperature up to 300C. This feature provides flexibility for various industrial applications, safeguarding process integrity while maintaining safety as per IS 3044 and IBR standards.


Customizable Design Specifications

Built to order, these heaters accommodate capacities from 100,000 to 2,000,000 Kcal/hr, supporting diverse installation spaces and operational requirements. Dimensions, tank diameter, and color are tailor-made to suit individual facility layouts and design preferences.

FAQs of Thermic Fluid Heaters:


Q: How does the Thermic Fluid Heater achieve high fuel efficiency?

A: The heater utilizes advanced combustion technology with a finned tubular coil heat exchanger and automatic firing mode to optimize fuel usage, resulting in up to 87% efficiency. This design ensures efficient transfer of heat to the thermal oil, minimizing wastage and reducing operational costs.

Q: What industries typically use this Thermic Fluid Heater for process heating?

A: This heater is designed for a wide range of industries, including chemical, pharmaceutical, textile, food processing, and manufacturing sectors needing reliable and consistent heat supply for industrial and process applications.

Q: When should I consider using a tankless, horizontal thermic fluid heater?

A: A tankless, horizontal unit is ideal when you need space-saving installation and rapid start-up. Facilities requiring quick heating, efficient oil circulation via pump, and easy maintenance will benefit from this configuration.

Q: Where can the Thermic Fluid Heater be installed, and can its size be customized?

A: The heater can be installed in industrial plants and process facilities. Its dimensions, tank diameter, and capacity are customizable based on installation site requirements and client specifications, ensuring seamless integration with existing setups.

Q: What is the process for controlling and monitoring the systems performance?

A: System performance is managed via a digital or automatic control panel, enabling precise temperature regulation and monitoring. Automatic firing mode ensures optimal combustion, while integrated safety features provide real-time diagnostics and secure operation.

Q: How is thermal oil circulated within the heater, and what are its advantages?

A: Thermal oil is circulated using a pump-driven mechanism, which guarantees consistent and uniform heat distribution throughout the system. This method enhances heat transfer, prolongs equipment life, and supports stable process temperatures.

Q: What are the main benefits of choosing this heater with IS 3044 / IBR construction standards?

A: By adhering to IS 3044 and IBR standards, the heater offers assured quality, safety, and compliance with industry regulations. This ensures reliable performance, long-term durability, and easier certification for industrial usage and export.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top